Battery Operated Combination Smoke & Carbon Monoxide Detector with Voice Alerts, 5300
Rely Essentials
Was:
$55.99
Now:
$52.99
- Enhanced detection technology - reduces nuisance alarms often caused by cooking and offers early warning. Carefully tested to meet the latest UL standards (meets UL 217 8th and 9th Edition)
- No wiring needed - Operates on a 9-volt battery (included) providing simple installation options
- 2-in-1 Detection - alerts for smoke and carbon monoxide in a single alarm
- Easy to use - The large Test/Hush button makes it easy to test the detector and silence false alarms
The Rely Essentials Battery Operated combination smoke and carbon monoxide alarm with voice alerts helps guide you to safety. This alarm meets new industry standards with advanced technology that offers early warnings and reduces nuisance alarms. The combined smoke and carbon monoxide detector provides dependable protection and is simple to install and maintain. Thoroughly tested and designed to meet the latest UL safety standards, this smoke alarm is powered by two AA replaceable batteries (included) for continuous detection even during power outages.
- Enhanced detection technology - reduces nuisance alarms often caused by cooking and offers early warning. Carefully tested to meet the latest UL standards (meets UL 217 8th and 9th Edition)
- No wiring needed - Operates on a 9-volt battery (included) providing simple installation options
- 2-in-1 Detection - alerts for smoke and carbon monoxide in a single alarm
- Easy to use - The large Test/Hush button makes it easy to test the detector and silence false alarms
- Loud 85db alarm
- Low battery warning
- LED lights indicates alarm status
- 10-year limited warranty
- Complies with the following authorities:
- Underwriters Laboratories (UL)
- National Fire Protection Association (NFPA)
- California State Fire Marshal (CSFM)
- POWER:
- 3VDC (ENERGIZER/GP AA*2 ) (replaceable)
- OPERATION CURRENT:
- <10uA (standby), <80mA (alarm)
- ALARM VOLUME:
- ≥85dB at 10ft@ 3.0 to 3.5 KHz pulsing alarm, with voice messages "Fire!" and/or "Warning! Carbon Monoxide."
- ALARM SENSITIVITY:
- Smoke Alarm Sensitivity: 2.08%/ft +/-25% OBS
- SILENCE Period:
- Smoke alarm silence: About 8 minutes, CO silence: About 5 minutes
- SMOKE ALARM SOUND PATTERN:
- Temporal 3 BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the red LED flash, repeat this alarm pattern
- COMPLY WITH:
- UL STD 217 8th Ed. & 2034 4th Ed.
- CO ALARM SENSITIVITY:
- 70 PPM: Between 60 to 240 minutes 150 PPM: Between 10 to 50 minutes 400 PPM: Between 4 to 15 minutes
- TEMPERATURE OPERATING RANGE:
- 40°F (4.4°C) to 100°F (37.8°C)
- HUMIDITY OPERATING RANGE:
- 10~95% RH non-condensing